Description
Features:
Model No: TA120
Product Name: AC DC Open Frame Switching Power Supply 24V 36V
* Ultra small shape design, easy to install
* Full load operation, low temperature rise
* Meet safety requirements, and isolation withstand voltage is greater than 3000VAC
*Compliant with EMC design, can be certified, low ripple processing.
* Optional synchronous rectification technology, higher efficiency and lower temperature rise.
* Output short circuit, over current, over power protection functions are perfect.
Remarks:
Focus on producing the following products:

| Electrical Parameters/Specifications | |||||
| Model No | TA121-24V3A | TA121-24V4A | TA121-24V5A | TA121-36V3A | |
| Output | DC voltage | 24V | 24V | 24V | 36V |
| Rated current | 3A | 4A | 5A | 3A | |
| Current range | 0-3A | 0-4A | 0-5A | 0-3A | |
| rated power | 72W | 100W | 120W | 100W | |
| Ripple and Noise (Maximum) | 80mVp-p | 80mVp-p | 100mVp-p | 120mVp-p | |
| Voltage accuracy | ±3% | ±3% | ±3% | ±3% | |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation | ±1% | ±1% | ±1% | ±1% | |
| Ikhono lokwenza (TYP) | 87% | 87% | 87% | 88% | |
| Voltage adjustment range | not adjustable | ||||
| Start-up, rise time | 1500ms,30ms/220VAC 2500ms,30ms/110VAC(full load) | ||||
| Input | voltage range | VAC90-264V VDC127~370V (Please refer to “Derating Curve”) | |||
| Frequency Range | 47~63Hz | ||||
| AC current (TYP) | 0.7A/220VAC,1.4A/110V | 1.1A/220VAC,2A/110V | |||
| Inrush current (TYP) | COLD START 35A | ||||
| leakage current | <2mA/240VAC | ||||
| Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
| over current | 110%~200% of rated output current | ||||
| over power | 110%~200% of rated output power | ||||
| Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to “Derating Curve”) | |||
| Working humidity | 20~90%RH, no condensation | ||||
| Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
| Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
| Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT, general standard design for home appliances | |||
| Pressure resistance | I/P-O/P:3KVAC | ||||
| Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
| Electromagnetic Compatibility Emissions | Refer to CE, CCC, IT, general standard design for home appliances | ||||
| Electromagnetic Compatibility Immunity | Refer to CE, CCC, IT, general standard design for home appliances | ||||
| Mechanical | Size (L*W*H) | 90*60*36mm(L*W*H) | |||
| weight | About 0.5Kg/PCS | ||||
| Remarks | 1. Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature. | ||||
| 2. Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth. | |||||
| 3. Accuracy: including setting error, linear adjustment rate and load adjustment rate. | |||||
| 4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. | |||||
| 5. Load regulation measurement method: from 0% to 100% rated load. | |||||
| 6. The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment. | |||||