Descriptio
Features:
Exemplar No: TA150
Product Name: OEM ODM AC DC Open Frame Switching Power Supple Manufacturer
* Ultra parva figura design, facile install
* Plena onus operandi, humilis temperatus ortum
* Dignum salutem necessaria, and isolation withstand voltage is greater than1500VAC.
* Strong anti-interference ability, humilis tremor processus.
* Libitum synchronum technologia, altiorem efficientiam et minus temperatus ortum.
* Output brevis-circuitu, super-current, per-potestatem tutelae munera perfecta sunt.
Remarks:

| Electrical Morbi / Specifications | |||||
| Exemplar No | TA150-24V5A | TA150-24V6A | TA150-36V5A | TA150-48V3A | |
| Output | DC voltage | 24V | 24V | 36V | 48V |
| Ratum current | 5A | 6A | 5A | 3A | |
| Current range | 0-6A | 0-6A | 0-5A | 0-4A | |
| Rated power | 120W | 150W | 150W | 150W | |
| Ripple et sonitus (Maximum) | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Accuratio intentione | ±3% | ±3% | ±3% | ±3% | |
| Linearibus temperatio rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Onus Ordinatione | ±1% | ±1% | ±1% | ±1% | |
| Efficientia (TYP) | 84%(220V MAX) | 84%(220V MAX) | 85%(220V MAX) | 85%(220V MAX) | |
| Voltage adjustment range | not adjustable | ||||
| Satus-up, oriri tempus | 1500ms,30ms/220VAC 2500ms,30ms/110VAC(plenum onus | ||||
| Input | voltage range | VAC90-264V VDC127~370V (Please refer to “Derating Curve”) | |||
| Frequency Range | 47~63Hz | ||||
| AC current (TYP) | 1.4A/220VAC,2.5A/110V | ||||
| Inrush current (TYP) | COLD START 35A | ||||
| leakage current | <2mA/240VAC | ||||
| Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
| over current | 110%~200% of rated output current | ||||
| over power | 110%~200% of rated output power | ||||
| Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to “Derating Curve”) | |||
| Working humidity | 20~90%RH, no condensation | ||||
| Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
| Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
| Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT', general standard design of home appliances, (customer certification test is required) | |||
| Pressure resistance | I/P-O/P:1.5KVAC | ||||
| Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
| Electromagnetic Compatibility Emissions | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
| Electromagnetic Compatibility Immunity | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
| Mechanical | Size (L*W*H) | 115*67*35mm(L*W*H) | |||
| weight | About 0.7Kg/PCS | ||||
| Remarks | 1. Unless otherwise specified, all specifications are measured under the input of 220VAC, rated onus, et XXV ° C temperatus ambientium. | ||||
| 2. Riple et sonitus mensurae modum: uti a 30CM perversa par funem, et terminales iungi debeant cum capaci- toribus 0.1uf et 47uf, et metimur ad 20MHZ Sed. | |||||
| 3. Sagacitas: inter occasum erroris, linearibus temperatio rate et onus temperatio rate. | |||||
| 4. Linearibus temperatio rate mensurae modum: sub rated onus, ex humili intentione ad alta intentione test. | |||||
| 5. Modus mensurae modum onus: e* 0% to 100% rated onus. | |||||
| 6. Potestas copia habenda pars partium in systematis, et talis confirmatio compatibilitatis electromagneticae peragi debet in coniunctione cum apparatu terminali. | |||||










Recognitiones
Nullae recensiones adhuc exstant.