Description
Features:
Model No: TA150
Product Name: OEM ODM AC DC Open Frame Switching Power Supply Manufacturer
* Ultra small shape design, easy to install
* Full load operation, low temperature rise
* Meet safety requirements, and isolation withstand voltage is greater than1500VAC.
* Strong anti-interference ability, low ripple processing.
* Optional synchronous rectification technology, higher efficiency and lower temperature rise.
* Output short-circuit, over-current, over-power protection functions are perfect.
Remarks:

| Electrical Parameters/Specifications | |||||
| Model No | TA150-24V5A | TA150-24V6A | TA150-36V5A | TA150-48V3A | |
| Output | DC voltage | 24V | 24V | 36V | 48V |
| Rated current | 5A | 6A | 5A | 3A | |
| Current range | 0-6A | 0-6A | 0-5A | 0-4A | |
| Rated power | 120W | 150W | 150W | 150W | |
| Ripple and Noise (Maximum) | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Voltage accuracy | ±3% | ±3% | ±3% | ±3% | |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation | ±1% | ±1% | ±1% | ±1% | |
| Efficiency (TYP) | 84%(220V MAX) | 84%(220V MAX) | 85%(220V MAX) | 85%(220V MAX) | |
| Voltage adjustment range | not adjustable | ||||
| Start-up, rise time | 1500ms,30ms/220VAC 2500ms,30ms/110VAC(full load) | ||||
| Input | voltage range | VAC90-264V VDC127~370V (Please refer to “Derating Curve”) | |||
| Frequency Range | 47~63Hz | ||||
| AC current (TYP) | 1.4A/220VAC,2.5A/110V | ||||
| Inrush current (TYP) | COLD START 35A | ||||
| leakage current | <2mA/240VAC | ||||
| Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
| over current | 110%~200% of rated output current | ||||
| over power | 110%~200% of rated output power | ||||
| Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to “Derating Curve”) | |||
| Working humidity | 20~90%RH, no condensation | ||||
| Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
| Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
| Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT, general standard design of home appliances, (customer certification test is required) | |||
| Pressure resistance | I/P-O/P:1.5KVAC | ||||
| Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
| Electromagnetic Compatibility Emissions | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
| Electromagnetic Compatibility Immunity | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
| Mechanical | Size (L*W*H) | 115*67*35mm(L*W*H) | |||
| weight | About 0.7Kg/PCS | ||||
| Remarks | 1. Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature. | ||||
| 2. Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth. | |||||
| 3. Accuracy: including setting error, linear adjustment rate and load adjustment rate. | |||||
| 4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. | |||||
| 5. Load regulation measurement method: from 0% to 100% rated load. | |||||
| 6. The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment. | |||||










Reviews
There are no reviews yet.