China manufacturer 10W 18W 24W Open Frame Power Supply

Features

Model No: TA12

Product Name: China manufacturer 10W 18W 24W Open Frame Power Supply

* Ultra small shape design, easy to install

* Full load operation, low temperature rise

* Meet safety requirements, and isolation withstand voltage is greater than 1500VAC

* Refer to EMC design, can be certified, low ripple processing.

* Optional synchronous rectification technology, higher efficiency and lower temperature rise.

* Output short-circuit, over-current, over-power protection functions are perfect.

Description

Features

Model No: TA12

Product Name: China manufacturer 10W 18W 24W Open Frame Power Supply

* Ultra small shape design, easy to install

* Full load operation, low temperature rise

* Meet safety requirements, and isolation withstand voltage is greater than 1500VAC

* Refer to EMC design, can be certified, low ripple processing.

* Optional synchronous rectification technology, higher efficiency and lower temperature rise.

* Output short-circuit, over-current, over-power protection functions are perfect.

Electrical Parameters/Specifications
Model No TA18-5V3A TA12-12V1.5A TA18-12V2A TA18-24V1A
Output DC voltage 5V 12V 12V 24V
Rated current 3A 1.5A 2A 1A
Current range 0-3A 0-1.5A 0-2A 0-1A
rated power 10W 18W 24W 24W
Ripple and Noise (Maximum) 50mVp-p 80mVp-p 80mVp-p 100mVp-p
Voltage accuracy ±5% ±3% ±3% ±3%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±1% ±1% ±1%
Efficiency (TYP) 78% 85% 85% 88%
Voltage adjustment range not adjustable
Start-up, rise time 1500ms,30ms/220VAC 2500ms,30ms/110VAC(full load)
Input voltage range VAC90-264V VDC127~370V (Please refer toDerating Curve”)
Frequency Range 47~63Hz
AC current (TYP) 0.3A/220VAC ,0.5A/110VAC
Inrush current (TYP) COLD START 35A
leakage current <2mA/240VAC
Current
Protection
short circuit Protection mode: hiccup mode, automatic recovery after abnormal condition is removed
over current 110%~200% of rated output current
over power 110%~200% of rated output power
Environmental Operating temperature ﹣20~﹢60℃ (Please refer toDerating Curve”)
Working humidity 20~90%RH, no condensation
Storage temperature and humidity ﹣40~﹢85℃,10~95%RH
Vibration resistant 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes
Safety and Electromagnetic Compatibility safety regulations Refer to CE, IT general standard design
Pressure resistance I/P-O/P:1.5KVAC
Insulation resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH
Mechanical Size (L*W*H) 65*32.5*16mm(L*W*H)
weight About 0.3Kg/PCS
Remarks 1. Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.
2. Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth.
3. Accuracy: including setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load regulation measurement method: from 0% to 100% rated load.
6. The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.