Description
Features:
Model No: TA65
Product Name: 50W 60W 72W open frame switching power supply Factory
* Ultra small shape design, easy to install.
* Full load operation, low temperature rise
* Refer to safety requirements, isolation withstand voltage is greater than 1500VAC.
* Refer to EMC design, can be certified, low ripple processing.
* Optional synchronous rectification technology, higher efficiency and lower temperature rise.
* Output short-circuit, over-current, over-power protection functions are perfect.
Remarks:
Focus on producing the following products:
open frame switching power supply

| Electrical Parameters/Specifications | |||||
| Model No | TA65-5V10A | TA65-12V5A | TA65-24V3A | TA65-36V2A | |
| Output | DC voltage | 5V | 12V | 24V | 36V |
| Rated current | 10A | 5A | 3A | 2A | |
| Current range | 0-10A | 0-5A | 0-3A | 0-2A | |
| rated power | 50W | 60W | 72W | 72W | |
| Ripple and Noise (Maximum) | 50mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | |
| Voltage accuracy | ±5% | ±3% | ±3% | ±3% | |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation | ±1% | ±1% | ±1% | ±1% | |
| Efficiency (TYP) | 88% | 85% | 88% | 89% | |
| Voltage adjustment range | not adjustable | ||||
| Start-up, rise time | 1500ms,30ms/220VAC 2500ms,30ms/110VAC(full load) | ||||
| Input | voltage range | VAC100-240V(85-264V) VDC127~370V (Please refer to “Derating Curve”) | |||
| Frequency Range | 50/60Hz | ||||
| AC current (TYP) | 0.6A/220VAC,1.2A/100V | 0.65A/220VAC,1.25A/100V | |||
| Inrush current (TYP) | COLD START 45A | ||||
| leakage current | <2mA/240VAC | ||||
| Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
| over current | 110%~200% of rated output current | ||||
| over power | 110%~200% of rated output power | ||||
| Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to “Derating Curve”) | |||
| Working humidity | 20~90%RH, no condensation | ||||
| Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
| Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
| Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements | |||
| Pressure resistance | I/P-O/P:3KVAC | ||||
| Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
| Electromagnetic Compatibility Emissions | Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements | ||||
| Electromagnetic Compatibility Immunity | Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements | ||||
| Mechanical | Size (L*W*H) | 130*50*30mm(L*W*H) | |||
| weight | About0.5Kg/PCS | ||||
| Remarks | 1. Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature. | ||||
| 2. Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth. | |||||
| 3. Accuracy: including setting error, linear adjustment rate and load adjustment rate. | |||||
| 4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. | |||||
| 5. Load regulation measurement method: from 0% to 100% rated load. | |||||
| 6. The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment. | |||||









Reviews
There are no reviews yet.